98, 118 or 130 Inches? Choosing an Electric Stacker Lift Height
A stacker that can raise its forks to your top rack level is not necessarily ready to work in your building. It also needs room to place the pallet, clearance for the mast and load, and enough verified capacity at that height.
If you are comparing the 98, 118 and 130 inch lift options on GETSUP's CTD15R-EN electric pallet stacker, collect the measurements below before choosing a variant. The tallest option is useful only when the complete configuration fits the job.
What the listed lift options tell you
| Listed lift height | Feet and inches | What still needs checking |
|---|---|---|
| 98 in | 8 ft 2 in | Required fork position and placement clearance |
| 118 in | 9 ft 10 in | Required fork position and placement clearance |
| 130 in | 10 ft 10 in | Required fork position and placement clearance |
These are listed lift heights, not guaranteed usable rack heights. They do not specify the lowered mast height, the height of the fully extended mast or the weight permitted at the top of the lift. Confirm those details for the exact variant supplied.
1. Measure the pallet support level, then check the fork position
Record the height from the floor to the surface that supports the pallet at the highest storage position. Use the actual pallet support surface, rather than the top of the rack upright or the overall height of the stored goods.
The forks enter the pallet above its underside. That geometry, together with the clearance needed to position and lower the pallet onto its supports, affects the required fork height. Send a pallet drawing or clear side photo with measurements so the relationship can be checked.
For example, if the pallet support surface is 118 inches above the floor, do not assume that a stacker listed with 118 inches of lift will serve it. The forks may need to rise higher to position the pallet. A 130 inch option is a candidate for review, not an automatic approval: the required clearance and load capacity still need confirmation.
2. Check the doorway and the lift location separately
There are two different mast measurements to request:
- Lowered mast height: compare this with the lowest clear opening along the travel route. Include door hardware, beams and other obstructions.
- Extended mast height: compare this with the available overhead space where lifting will take place. The mast can extend above the forks.
Check the top of the raised load as well. A tall palletized load and an extended mast occupy different parts of the overhead space. Include lights, ducts, sprinklers and beams in your measurements, and have the necessary clearances reviewed for the site. Ceiling height alone is not enough.
3. Confirm capacity at the selected height
The CTD15R-EN listing gives a 3,300 lb rated capacity. Do not read that as confirmation that every variant can lift every 3,300 lb load to its maximum height.
Ask for the capacity information for the exact mast, working height and load centre. Provide the gross weight, including pallet and packaging, plus the load's depth and weight distribution. A long or uneven load needs specific review. Do not estimate the available capacity by applying a percentage to the headline rating.
For comparison, GETSUP also lists the CPD10W-II counterbalanced stacker with a 118 inch maximum listed lift and 2,200 lb rated capacity. Its configuration has no front outriggers, which may help where support legs interfere with the pallet or rack. That does not remove the need to check capacity, pallet fit, mast dimensions and turning space.
4. Collect a complete set of measurements
A useful fit review starts with:
- The highest pallet support level and a photo of the rack bay.
- The heaviest gross load, load dimensions and any uneven weight distribution.
- Pallet side and underside photos, entry openings and overall dimensions.
- The lowest doorway or route obstruction and overhead measurements at each lift position.
- The clear aisle width, tightest turn and space to approach the rack with the actual pallet.
- Floor condition, expected lifts per day and delivery unloading access.
The stacker's capability does not establish the rack's load capacity. Check the rack and pallet supports independently. Our electric stacker buying guide covers the broader fit review.
Frequently asked questions
Should I choose 130 inches just to allow for future storage?
Only after checking the proposed storage height, load, lowered mast and extended mast dimensions. Future lift capacity is useful when the configuration also fits the route and building.
Does a 118 inch lift rating mean the mast is 118 inches tall?
No. Lift height, lowered mast height and extended mast height are separate specifications. Request the dimensional drawing for the selected unit.
Can two stackers with the same lift height serve the same rack?
Not necessarily. Their capacity at height, forks, support legs, chassis dimensions and turning requirements can differ.
Get the height and fit checked before ordering
Compare the electric stacker range, then send your measurements to info@getsupinc.com or call 905-569-8898. GETSUP can review the application and confirm the supplied configuration, current availability, Mississauga pickup or Canada-wide delivery options before you order.